Several times now, I have considered deleting this article from my
website because it is not significantly applicable to a home workshop
dust collection system. However, I have received enough email questions
from industrial applications to realize that removing this information
would be a great disservice to those people where this information is
most critical.
If you are reading this article because you have a home workshop
dust collection system with PVC piping, then don't panic with what you
read below. However, if you are in an industrial application, then you
should take heed to this information. I almost deleted this article
last month when I cleaned up my website, but today I received another
email from a non-woodworking relating reader where an explosion hazard
is extremely great. It is for this reason that I am maintaining this
article.
I do not condone the use of PVC ducting for dust collection systems, and this article should not be construed as a solution to that end. The original purpose of this discussion was to cover one specific aspect of this discussion, and it remains to be the primary focus, however, it does also cover many other aspects in reaching this goal. It was stated by some at the time, that a wire wrapped around the outside of a PVC line is just as effective as a wire on the inside. This conclusion is not correct, and the following discussion is geared toward that purpose.
In addressing this one issue, this treatise does cover many educational discussions, and frankly, some of them get pretty deep into electrical theories. Much of this cannot exactly be classified as light reading (although I have stripped out some of the tech-talk from the original discussions).
What you do in your shop is not for me to dictate, and so I have added some information to this subject to assist you, should you choose to proceed. I also acknowledge the realities of home-shop dust collection systems, in that they may be less prone to the problems of static-induced dust explosions.
The plastic rod strips electrons away from the fur, thereby giving the plastic a net, negative charge. The same situation occurs when an air/dust mixture passes over a plastic surface. The plastic will extract electrons from the flowing air. This will make the plastic negatively charged and the air/dust positively charged.
Static charge is the result of an area or surface having too many electrons (negative charge), or too few electrons (positive charge).
Static Versus Flowing Electricity
Static electricity is just as it sounds; the electrons are
not moving, but are stationary or "static". The electrical current
flowing through the wires in your home is made up of electrons. In
this case, the electrons are moving or "flowing". This is the only
distinction between static electricity and flowing electricity. When
static electricity suddenly moves, like in a spark, it is no longer
static. (Just in case there is a nuclear physicist reading, this is a
macroscopic discussion to avoid confusion or argument.)
Electric Charge and Insulators
An insulator is a material which does not readily permit the
movement of free electrons. While there is actually no
material which is a perfect insulator, the resistivity of insulators
is so high, that they are for all practical purposes, completely
non-conducting. The resistivity for fused quartz is 1025
times greater than that of copper. (that's 10 to the power of 25)
Which means fused quartz is ten-billion-billion-billion-billion times
more resistive than copper. I unfortunately do not have resistive
values for other insulating materials, but suffice it to say, the
values are quite large before they are even considered insulators.
Because an insulator like glass, plastic, or PVC does not permit the movement of electrons, the charge placed on these materials (by rubbing with silk, etc) will remain in the same place where it was rubbed. One end of a glass rod will be charged while the other end, which you are holding will not be charged.
Contrary to initial belief, you can also charge a metal rod in the same fashion, but the charge placed on the rod will spread out across the whole surface. If you are touching the rod with your hand (you are also a conductor) the charge will dissipate (spread out) through you as well. The difference between the metal rod and the plastic rod is that the charge will "spread out" in the metal rod. Like charges will repel one another, and the electrons, which are free to move in metals, will spread themselves out across the entire surface of the metal rod (or in our case, the entire dust collection system.) As a result, the entire system will be at the same voltage.
In one of the Internet discussions, someone mentioned that the charge on a PVC pipe will flow around the outside of the PVC or across the surface and equalize. If that were the case, then the rod used in Ben Franklin's experiment would have discharged into his body, and he never would have developed the concept of positive and negative charge. (Well, maybe he got frustrated doing all that rubbing for nothing and went out and flew his kite--who knows?)
Dielectric Breakdown
The two terms, insulators and dielectrics
mean the same thing, just different terminology, but dielectric is a
common term when discussing static charge. An insulator or dielectric
will not, in practical terms, permit the flow of electricity. Air is
a dielectric, yet we see lightning all the time. I just said that
lightning (or a spark) is the sudden flow of electricity, so how can
this be? Isn't that contradictory? No.
If there is a large enough voltage across an insulator, the insulation will breakdown, electrons will suddenly flow, and a spark will result. In our case, sparks are bad, as they also generate heat, and heat can ignite flammable materials. The voltage necessary for breakdown is dependent on both the material in question, and the thickness of the material. Furthermore, the longer the spark, typically, the hotter it gets. (Any mechanic will tell you this, with regard to the sparkplug gap setting.)
The primary point about dielectric breakdown, is that it takes far, far less voltage for a spark to jump through air, than it does to jump through PVC. This is the reason why it is absolutely pointless to wrap a ground wire around the outside of a PVC duct and expect protection against static buildup on the inside.
Below is a table of dielectric breakdown voltages for various materials. I have taken the liberty to convert these numbers into inches from the original millimeter data. This data is in the form of volts per inch of insulator. What this data tells us, is that it takes nearly 160,000 volts before a 1/8 inch thick PVC pipe will breakdown, and allow current to flow from the inside of the PVC to the outside where the ground wire is (I used polyethylene since PVC is not provided--1,270,000 volts per inch = 160,000 volts per 1/8 inch). Working backwards with this voltage, this translates into a spark in air which is nearly eight inches long! (That is one hot spark!)
Material |
Dielectric |
Thickness needed |
Vacuum |
infinite |
N/A |
Air (stp) |
20,320 |
4.9" |
Water |
Conducts |
N/A |
Paper |
355,600 |
0.28" |
Fused Quartz |
203,200 |
0.49" |
Bakelite |
304,800 |
0.33" |
Polyethylene |
1,270,000 |
0.08" |
Polystyrene |
635,000 |
0.16" |
Neoprene |
304,800 |
0.33" |
In short, we will have a spark in the air long before we can dissipate the charge to the outside of the PVC.
The spark that travels can either be between the negatively charged PVC and the positively charged air, or it can be from surface to surface on the PVC. Since the PVC does not conduct, it will not equalize the charge throughout the length or even diameter of the pipe. As a result, there is the potential for the spark to jump from one section of the PVC to another. Even an internal ground wire will not prevent this, as the wire only covers a small portion of the surface.
Explosion
Any material that can burn can also explode under the right
conditions. (I think it may even be possible for non-flammable
materials to explode too.) This all relates to the concentration of
the material. If the concentration is too low, then there is not
enough proximity between particles to support a chain reaction. If
the concentration is too high, then the mixture is considered too
rich, and there will not be enough air available for rapid
combustion. These two concentration levels are called the Lower
Explosive Limit (LEL) and the Upper Explosive Limit
(UEL). Looking at gasoline for example. It should be fairly obvious
that too little concentration will not explode, otherwise gas
stations would literally be "popping up" everywhere. What is a little
more difficult to understand is the concept of the UEL. Do not try
this! But I saw a match dropped into a small container of gas.
Since there was not enough oxygen for combustion, there was no fire
or explosion--the match went out. (This was a scientific
demonstration under controlled conditions by an expert, do not try it
yourself.)
I am not aware of any published LEL or UEL for sawdust as these numbers will vary depending on particle size, moisture content, etc. what I do know is that the finer the dust particle size, such as from a sander, the lower the concentration needed to combust.
Some Reality Checks
Q: Why doesn't
my shop vac explode?
A: Because the air velocity in a shop vac is
high, the static build up is also very high, and sparks happen
frequently inside the hose. However, the same high velocity of the
air also reduces the chance for an LEL concentration to develop
within the hose. In this case, you have the ignition source, but
don't have the explosive concentration.
Q: Why are there so few occurrences of
explosions in home shops?
A: Home shop explosions are not impossible, but
they are rare. This is because you need both an LEL concentration and
an ignition source at the same time and same place. The odds are low,
but not zero.
When you are sanding, not only is the LEL concentration likely to occur, but the increase in particulate will also increase the frequency of electrical discharges within the pipe--it is just a matter of timing.
When you are cleaning out your ductwork system, not only do you have electrical discharge present from particulate travel, but you will also have frequent occurrences of LEL concentrations, whether in small pockets, or throughout the length of the system. The chances here are much higher.
Q: I have never had a dust explosion before, so
why should I expect one in the future?
A: How do you know you have never had a minor
dust explosion contained within the ducting? Not all dust explosions
are catastrophic. Most are isolated to the limited space were an LEL
concentration exists, and burn out quickly enough so as not to ignite
the remainder of the dust system. I've never had a car accident
before, but that doesn't mean I don't need my seat belt!
Q: Some publications have stated that I can
wrap the outside of the PVC with a ground wire and be protected. Is
this correct?
A: No! Wrapping the outside of the PVC will
seem to be effective from the outside because the amount of static
there is reduced. However, the danger is not on the outside of the
pipe, it is on the inside of the pipe. Refer to the discussion on
dielectrics to see why it makes no difference what happens on the
outside.
Q: I have heard that I should run a wire
through the inside of the pipe, and a second spiral around the
outside for best protection. Does this add to my protection?
A: No! Wrapping the wire around the outside is
a "convenience" issue for the operator, not a safety issue. This wire
will reduce the "nuisance" jolts that someone may get in touching the
outside of the pipe, or reduce the amount of dust piling up on the
surface, but it has no bearing on the internal charges within the
pipe, and again, the inside is where the danger is. It won't hurt to
wrap the outside, but it adds no safety to the risk of explosion.
Q: I have heard that it is OK to have the wire
outside as long as I drill holes and install rivets or screws through
the PVC since these are penetrating into the inside area.
Correct?
A: No! By following the same discussion on
dielectrics as before, the sporadic spacing of the screws or rivets
is not enough to eliminate potential arching. Using the analogy from
above, the sparkplug on your car is hot enough to ignite gasoline
with only a 1/16 inch gap. How close are your rivets going to need to
be to prevent a hot enough spark to ignite the dust? (Much closer
than 1 inch apart! That's for sure.)
Q: I am going to run a wire through the inside
of the pipe, but I have heard that I can use insulated wire, is this
correct?
A: No! Using insulated wire will not help
whatsoever. It must be bare wire.
Q: I have been told by an electrician that the
ground wire for my dust collection system should be connected to an 8
foot copper rod driven into the ground for proper protection. My shop
is all concrete, so how can I do this?
A: Save your money and your sweat. This is not
necessary. The primary concern of the system is to keep all points at
the same voltage. The amount of current flowing through the ground is
very low, and any grounding location will suffice.
Q: Should I connect the ground wire through the
pipes to the dust collector chassis, the tool chassis, or both?
A: To be safe, I would connect the wire to both
the dust collector chassis and the tool chassis. This prevents any
voltage difference between either device and the ductwork.
Q:So if running a ground wire inside the PVC
still doesn't guarantee protection, what is the point in grounding at
all?
A: I do not know if grounding a system helps to
eliminate static discharges, but it should help in reducing them.
There are no guarantees except metallic ducting. It will probably
reduce the chances, but what I do know is that a wire wrapped around
the outside is of no use to this end.
Q: Should I use PVC for the ducting?
A: This is the BIG question. I would recommend
against it, but you should check for yourself. You may be surprised
at the low cost of HVAC ductwork. Because the home dust collection
system does not generate high static pressures, normal heating duct
will work quite well without collapsing.
Q: If I install metallic ducting, do I need to
worry about grounding the system?
A: Not really. The only exception would be if
you used plastic blast gates. Even in this case, the static build up
is minimal, and probably not worth the bother.